This is an icon box

Write a short description, that will describe the title or something informational and useful.

  • YF-400T Medical Waste Incinerator

    Combustion Control System

    Provides air supply and temperature control to optimize the combustion process. Primary and secondary air supply systems are available.

    Yanma Kontrol Sistemi
  • YF-400T Medical Waste Incinerator

    Safe Disposal

    Complete incineration of medical waste at high temperatures ensures the destruction of harmful microorganisms and toxic substances.

    Safe Disposal
  • YF-400T Medical Waste Incinerator

    Environmentally Friendly

    With advanced gas cleaning systems, emissions are kept to a minimum and the environment is not harmed.

    Environmentally Friendly
  • YF-400T Medical Waste Incinerator

    High Efficiency

    The highly efficient incineration process ensures fast and efficient disposal of waste.

    High Efficiency
  • YF-400T Medical Waste Incinerator

    Amount of Waste Reduced

    Leaves less end product than other methods. There is no possibility of contamination of the final product and no risk of viruses or bacteria in the flue gas.

    Azaltılmış Atık Miktarı
  • YF-400T Medical Waste Incinerator

    Durability and Longevity

    They are manufactured using materials that are resistant to high temperatures and have a long service life. This ensures reliable operation of the ovens for a long time.

    Dayanıklılık ve Uzun Ömür
  • YF-400T Medical Waste Incinerator

    Health and Environmental Safety

    Safe disposal of hazardous waste minimizes environmental and health risks.

    Sağlık ve Çevre Güvenliği
    Our YF-400T Series Medical Waste Incinerator is a Critical Solution for Health and Environmental Safety

    Medical wastes are wastes generated by hospitals, clinics, laboratories and other health institutions operating in the health sector, which carry a risk of infection and can be harmful to the environment. These wastes can pose serious health and environmental risks if not disposed of properly and safely. Our YF-400T Series Medical waste incinerators are important devices that ensure the safe and effective disposal of such wastes. Medical wastes are classified as hazardous wastes due to their nature and should be disposed of as soon as possible where they are generated. Infected waste can cause the spread of infectious diseases and environmental pollution. Therefore, safe and effective disposal of medical waste is vital.

    Advantages of YF-400T Series Medical Waste Incinerator

    Our YF-400T Series Medical waste incinerator ensures that harmful microorganisms and toxic substances are neutralized by completely destroying these wastes with high temperature incineration process. With advanced gas cleaning systems, emissions are kept to a minimum and the environment is not harmed. The highly efficient incineration process ensures fast and efficient disposal of waste. Leaves less end product than other methods. There is no possibility of contamination of the final product and no risk of viruses or bacteria in the flue gas. It is produced using high temperature resistant and long-lasting materials. Our YF-400T Series Medical waste incinerator works reliably for long periods of time.

    YF-400T Medical Waste Incinerator General Specifications

    Our YF-400T Series medical waste incinerator is available in various capacities and specifications. High operating temperatures ranging between 800-1200°C ensure complete combustion of waste. Complete combustion is ensured with a minimum gas retention time of 2 seconds. A more efficient combustion process is realized with a double combustion chamber (primary and secondary). Stainless steel chimney provides durability and long life. Harmful gases are filtered with chimney washing system. It can operate with natural gas or fuel oil. Dual fuel operation can also be preferred. Waste can be loaded with manual or fully automatic feeding system. Reliable burner brands such as Ecoflam and Riello are used in our incinerator. Different burner brands can be used according to customer preference.

    Chimney Washing Systems

    The YF-Series Medical Waste Incinerator safely disposes of medical waste. However, at high temperatures, harmful gases and particles are released, posing a threat to the environment and health. Flue scrubber systems reduce these emissions, neutralize acidic gases and capture fine particles.

      ✔   Wet Washing Systems: Gases come into contact with the liquid solution, harmful substances are removed from the solution. Highly efficient and wide gas and particle treatment.

      ✔   Dry Washing Systems: Gases come into contact with the solid adsorbent, harmful substances are attached to the adsorbent. Low water consumption, maintenance and operating costs are advantages.

      ✔   Semi Dry Washing Systems: The gases are brought into contact with both liquid and solid treatment media. This method is a combination of wet and dry washing systems.

      Automatic Loading

      Our automated loading systems ensure continuous feeding of medical waste into the YF-400T Series incinerator. This guarantees uninterrupted operation of the incinerator and maximum efficient combustion.

      Medical waste is homogeneously distributed in the furnace so that the combustion process is more efficient and the waste burns evenly. Provides a safe working environment by reducing operators' direct contact with waste during manual feeding. Automated loading systems reduce the risk of exposure to operators, saving time and allowing them to focus on other tasks.

      Automatic Ash Discharge

      Our YF-400T Series incinerator safely and efficiently processes medical waste, resulting in a large amount of ash. Regular and safe ash discharge is critical to the efficient operation of the incinerator and operator safety. Our automatic ash discharge systems automate this process, improving efficiency and safety.

        ✔   Efficiency: Automatic ash discharge systems ensure that the ash is discharged regularly and in a timely manner, ensuring the continuous efficient operation of the furnace.

        ✔   Safety: It prevents operator exposure and potential accidents that may occur during the manual ash discharge process, thus increasing operator safety.

        ✔   Labor Savings: Automated ash disposal systems allow the workforce to focus on more strategic and efficient tasks, thus reducing operating costs.

        Gas Retention Time

        Full combustion is ensured with a minimum gas hold time of 2 seconds.

        Combustion Chambers

        A more efficient combustion process is realized with a double combustion chamber (primary and secondary).

        Safe Disposal

        Complete incineration of medical waste at high temperatures ensures the destruction of harmful microorganisms and toxic substances.

        Environmentally Friendly

        With advanced gas cleaning systems, emissions are kept to a minimum and the environment is not harmed.

        Technical Specifications
        MODEL
        YF-400T
        CAPACITY
        400 KG/S
        FEEDING
        MANUAL
        ASH DISCHARGE
        MANUAL
        SECOND COMBUSTION CHAMBER
        AVAILABLE
        WORKING TEMPERATURE
        850-1200 °C
        INCINERATOR INTERIOR
        FIRE CONCRETE
        ISOLATION
        CERAMIC FIBER
        CHIMNEY WASHING
        AVAILABLE
        BRUILDER BRAND
        ECOFLAM
        GAS HOLDING TIME
        2 SEC
        Optional Features
        Pre-shredding Machine
        Heat Recovery System
        Automatic Loading
        Automatic Ash Discharge
        Dry Chimney Washing System
        Semi-Dry Chimney Flushing System
        Gas Filtration System
        Emission Monitoring System
        Production in Different Capacities
        Different Brand Burners
        Automatic Temperature Control System
        Frequently Asked Questions (FAQ)

        A medical waste incinerator is a device that enables the disposal of medical waste from hospitals, clinics, laboratories and other health institutions that carry the risk of infection and may be harmful to the environment by burning at high temperatures.

        Medical waste is loaded into the incinerator and burned in the combustion chamber at high temperatures. During this process, harmful microorganisms and toxic substances are completely destroyed. Emissions are kept to a minimum thanks to advanced gas cleaning systems.

        Infectious wastes, medical wastes, delivery room wastes, expired drugs, operating room wastes, biomedical wastes, pathological wastes, pharmacy wastes, needles, infusion sets, knives, glassware, anti-cancer chemotherapy materials, cytostatic drugs, genotoxic chemical wastes, laboratory reagents, disinfectants and pharmaceutical wastes

        Medical waste incinerators generally operate between 800-1200°C. These high temperatures ensure complete combustion of the waste and the destruction of harmful microorganisms.

        Gas cleaning systems filter harmful gases and particles formed during combustion, keeping emissions released into the environment at a minimum level. Different methods such as wet, dry and semi-dry washing systems can be used.

        The capacity of the medical waste incinerator varies according to the model. For example, the capacity of YF series furnaces varies between 5 kg/hour and 1000 kg/hour.

        The automatic loading system ensures that medical waste is continuously fed into the incinerator. This system guarantees a homogeneous distribution of the waste and the efficiency of the combustion process. It also increases safety by reducing operators' direct contact with hazardous waste.

        The automatic ash discharge system ensures that the ash produced by the combustion process is discharged regularly and safely. This system improves the efficient operation of the furnace and operator safety.

        Thanks to advanced gas cleaning systems, medical waste incinerators keep emissions to a minimum and ensure safe disposal of waste without harming the environment. These systems prevent the release of harmful gases and particles into the environment.

        The furnace should be checked and maintained regularly. The furnace and flue systems must be cleaned regularly. Worn or damaged parts must be replaced in a timely manner. Gas cleaning systems require regular maintenance and cleaning to ensure effective operation.

        Reliable burner brands such as Ecoflam and Riello are generally used in medical waste incinerators. Different burner brands can also be used according to customer preference.

        Yes, medical waste incinerators are produced in different capacities. YF series incinerators are available in capacities ranging from 5 kg/h to 1000 kg/h.

        Medical waste incinerators are manufactured in accordance with national and international environmental and health safety standards. These standards set requirements for emission control, safe disposal and environmental protection.

        en_USEN